vialroom

#test-results 2025-07-13

Sunday57 messages10 participantstimes are UTC
Highlights from this day
  • provincial_pat — if you are testing to settle an argument you will not settle it with n of 1 20:04
  • ten_of_ten — follow up a supplier disputing a result is rare here and it has never gone well for the supplier 20:47
  • assay_not_purity — the widest spread in my data is about 2.6 percentage points across five lots from one supplier 20:54
  • VialBot — New independent result logged — FGP, lot A-2418, purity 98.6% (PeptideMeter). 21:32
A1

update from 21 months ago: retested the same supplier, result came back better, logged both

assay under label with good purity means you got less of the right thing. that is a fill problem, not a synthesis problem, your mileage will differ

HL

99.4 against a certificate of 98.1 is fine. the same supplier landing low four times in a row is a question

has a supplier ever disputed a result posted here

nice result

whats the lot

sample handling on your end absolutely affects it. draw cleanly, ship fast, do not let it sit warm

unrelated but a single sample tells you about a single vial. that is genuinely all it tells you

one bad test does not condemn a supplier. one good test does not clear one. both halves get ignored equally

posting my Medutest result on lot B-0329, what do people make of it

IS

i told SSA about a result they would not have liked and they did not argue. credit where it is due

PP

if you are testing to settle an argument you will not settle it with n of 1

📈11⚠️7

weigh it first

the honest limits: hobby chain of custody is weak and any result here should be read with that in mind

selection bias

anyone tested the same lot twice at different labs

is anyone tracking results over time in a way they would share
what interests me is when the gap goes the same direction every time. once is noise, three times is a pattern

A1

whats the underfill rate people are actually seeing

A1

coming back after 10 months with a follow up result, where do i put it

😂4

my sheet has 3 lots from CPC with a spread under a point, which is tight, n of 1 obviously

log the boring results too. a channel that only records failures produces a false picture, someone check my working

*that should say weekly

AN

test it again

lot        bought    purity   assay/label
A-2418     2025-03   99.1%    9.6 / 10mg
A-2601     2025-08   98.7%    9.8 / 10mg
B-0114     2026-01   99.3%    9.4 / 10mg
B-0329     2026-04   98.9%    9.9 / 10mg
TO

anyone had a result they think was a lab error rather than a bad vial

follow up a supplier disputing a result is rare here and it has never gone well for the supplier

🎉2📉6
AN

the widest spread in my data is about 2.6 percentage points across five lots from one supplier

⚠️8📉12

underfill is more common than impurity. if you only test purity you are testing the less likely failure

TO

my read after three years of this: purity is mostly fine across the market and fill consistency is where suppliers differ

TO

if the vial has been through a bad transit you are testing the transit as much as the supplier

what interests me is when the gap goes the same direction every time. once is noise, three times is a pattern

*VendorInvestigate not the other one

thats not great

VB

Channel stats, last 30 days: 77 messages from 10 members.

HL

post the lot, the purchase month, the lab, the number, and what you were expecting. that makes it useful later

VB

New independent result logged — FGP, lot A-2418, purity 98.6% (PeptideMeter).

TO

quantity testing is usually a separate line item and it is the one worth paying for

sorry to jump in weigh the vial before you reconstitute. it costs nothing and catches the common failure
the results in this channel skew because people test when they are suspicious. that is selection bias and it is real

LM

how do you post a result so it is actually useful to somebody in a year

i had a result i am fairly sure was a handling error on my side and i logged it as such

a result without a lot number and a purchase date is an anecdote with a pdf attached

follow up the results in this channel skew because people test when they are suspicious. that is selection bias and it is real

log the lot number