  • knees_first — it should be completely clear with no floaters. cloudy means stop weighing the vial before you reconstitute is the only way to catch an underfill 20:43
  • batch_bandit — my rule is one concentration for everything so i never have to think about it at 7am 20:54
  • batch_bandit — what do you do with the last 25 units when you cant draw them cleanly i use bac water even for a single-use vial because it stings less, which is not the reason it… 20:57
  • batch_bandit — genuine question the last few units are a real loss. i accept it rather than tilting the vial and drawing air, for what its worth 22:13
KF

it should be completely clear with no floaters. cloudy means stop
weighing the vial before you reconstitute is the only way to catch an underfill

KF

a slightly collapsed cake is cosmetic. a puddle in the bottom is not

BB

my rule is one concentration for everything so i never have to think about it at 7am

⚠️6👍1

what do you do with the last 25 units when you cant draw them cleanly
i use bac water even for a single-use vial because it stings less, which is not the reason it exists

bacteriostatic water for anything multi-use. sterile water has no preservative in it at all, from memory

FT

the meniscus thing is real. read it at eye level or you are guessing by a unit either way

[edited]
FT

label the date too. you will not remember which vial is which by week 4

BB

dead space in a standard insulin syringe hub is small but it is not nothing over a month

BB

10mg in 2ml is 5mg/ml. so 0.5mg is 0.1ml which is 10 units on a u100

genuine question the last few units are a real loss. i accept it rather than tilting the vial and drawing air, for what its worth

DD

im getting bubbles in the barrel every single time, what am i doing wrong