vialroom

#reconstitution 2025-11-28

Friday48 messages11 participantstimes are UTC
Highlights from this day
  • gus_charts — bacteriostatic water for anything multi-use. sterile water has no preservative in it at all temperature of the diluent does not matter. how fast you push it in does 16:02
  • chlorhex — pick the volume so your dose is a whole number of units. thats the entire trick 16:18
  • blind_submit — if you cannot read the mark confidently, your volume is too small. redo it at a lower concentration 17:56
  • yyz_vial — you can absolutely just always use 2ml, and honestly most of us should 19:29
15:00cedar_counts joined the room

aim the diluent at the glass wall, not at the powder. it goes in gentler

PF

bac water or sterile water for something im going into weekly for 8 weeks

PF

30mg in 3ml is 10mg/ml, so 5mg is 50 units. half the barrel, feels like a lot but its right

follow up does it matter if i inject the bac water straight at the powder

PF

5mg in 2ml gives 2.5mg/ml, 0.25mg is 10 units. good for a starting dose, not advice obviously

im getting bubbles in the barrel every single time, what am i doing wrong

CH

if i add 2ml to a 5mg vial what concentration am i actually at

GC

bacteriostatic water for anything multi-use. sterile water has no preservative in it at all
temperature of the diluent does not matter. how fast you push it in does

[edited]
❤️13💀9🧊2
CH

i was wrong about this last year: it is fine to draw cold, it just stings more going in, anyway

pick the volume so your dose is a whole number of units. thats the entire trick

🤝9😂3❤️15
GC

the vacuum will pull it in. let it. fighting it is how you get a face full of aerosol

TM

thats fine

U-100 syringe: 1 unit = 0.01 ml
  10u = 0.10 ml
  25u = 0.25 ml
  50u = 0.50 ml
 100u = 1.00 ml
mg drawn = ml drawn x mg/ml
GC

unrelated but a 3ml syringe for the diluent and a u100 for the dose is the setup most people here end up with

if the maths gives you 13.7 units, change the volume. do not try to hit 13.7

CC

is the meniscus reading actually a real source of error or am i overthinking

CH

how long after reconstituting before its actually dissolved

CC

my rule is one concentration for everything so i never have to think about it at 7am, i think

BS

dead space in a standard insulin syringe hub is small but it is not nothing over a month

BS

temperature of the diluent does not matter. how fast you push it in does

PF

is it worth buying a 3ml syringe for the diluent or is the insulin one fine

BS

if you cannot read the mark confidently, your volume is too small. redo it at a lower concentration

vial-c-4402-front.png
900 × 1200 · 846 KB · not retained in the public archive
BS

slightly off topic but anyone worked out a recon volume that puts 0.5mg on a round unit mark

chromatogram-overlay.png
1240 × 720 · 901 KB · not retained in the public archive
AA

update from 18 months ago: switched to a single concentration and have not miscalculated since, ill dig out the number

swirl it. do not shake it. the foam is denatured protein and you are not getting it back

YV

a slightly collapsed cake is cosmetic. a puddle in the bottom is not

YV

you can absolutely just always use 2ml, and honestly most of us should

❤️3😂6⚠️1

foam is bad

why does everyone say 2ml specifically and not 1ml

VI

20mg in 2ml is 10mg/ml. 1mg is 10 units, 2mg is 20 units, easy
the jewellery scale is a good habit but calibrate it, they drift badly

i swirl for about thirty seconds and then leave it. never had one fail to dissolve, for what its worth

🧊1
VI

i have never once regretted using a rounder number and a slightly bigger volume