10mg in 1ml is 10mg/ml, so 2.5mg is 25 units. thats the one i use
#reconstitution 2025-08-24
- taper_or_not — for the archive swirl it. do not shake it. the foam is denatured protein and you are not getting it back 15:49
- blank_run — bacteriostatic water for anything multi-use. sterile water has no preservative in it at all the meniscus thing is real. read it at eye level or you are guessing by a… 16:12
- VialBot — Batch lookup A-2418: 6 independent reports on file, earliest 2024-11-11. 16:30
lyophilised powder is far more robust than people think. it is the solution that is fragile
if the powder is on the stopper, tap it down before you add anything. it will still dissolve either way
10mg in 1ml is 10mg/ml, so 2.5mg is 25 units. thats the one i use
weigh it first
for the archive swirl it. do not shake it. the foam is denatured protein and you are not getting it back
bac water
if you draw up with a bigger pin and inject with a fresh one you lose a bit more to dead space
bacteriostatic water for anything multi-use. sterile water has no preservative in it at all
the meniscus thing is real. read it at eye level or you are guessing by a unit either way
Batch lookup A-2418: 6 independent reports on file, earliest 2024-11-11.
benzyl alcohol is what makes it bacteriostatic. it is about 0.9% typically, ask me again in a month
30mg in 3ml is 10mg/ml, so 5mg is 50 units. half the barrel, feels like a lot but its right
the jewellery scale is a good habit but calibrate it, they drift badly
gross powder mass is not net peptide. water and counterion are in that number
round numbers
sanity check my maths before i pin myself with something stupid
aim the diluent at the glass wall, not at the powder. it goes in gentler
check your maths
i was wrong about this last year: it is fine to draw cold, it just stings more going in
thats 5mg/ml
one unit is 0.01ml. 100 units is 1ml. everything else in this channel follows from that
it foamed. is it ruined
foam is bad
not sterile water
do you let it come to room temp before drawing or draw it cold
is it normal for the cake to look slightly collapsed on one side
give it 6 minutes at room temperature before you decide it has not dissolved
dead space in a standard insulin syringe hub is small but it is not nothing over a month
does benzyl alcohol matter if im finishing the vial in one go
does it matter if i inject the bac water straight at the powder
coming back to this is the meniscus reading actually a real source of error or am i overthinking
dead space
my 10mg vial weighed 11.4g on the jewellery scale, is that wrong
nope, redo it