  • fibre_first — mixed fonts and inconsistent kerning in one document is worth a second look 19:12
  • lot_number_lou — if the certificate date precedes the lot date, ask. sometimes it is sloppiness and sometimes it is not 20:10
  • lot_number_lou — ok so residual solvents matter more than people think for anything that went through a lot of purification steps 20:44
  • lot_number_lou — does anyone keep a folder of certificates to compare over time 21:21
  • lot_number_lou — sterility and endotoxin are separate tests and almost nobody runs either on research material, we shall see 21:23
FF

mixed fonts and inconsistent kerning in one document is worth a second look

🎉15📉6
FF

right so the retention time on this one is different from the last lot, problem

❤️5
NS

water content is why an honest 10mg vial assays at 9.1. karl fischer titration, and most certificates omit it

how do you verify a certificate is actually from the lab it says

test it yourself

LineClaimsDoes not claim
Purity (area %)fraction of detected material that is the targethow many mg are in the vial
Assay / contentmg of target per vialthat it is sterile
Water contentmass fraction that is wateranything about purity
Counterionsalt form and its mass sharenet peptide unless stated
Related substanceswhat else was seenwhat was not looked for

tfa counterion runs higher by mass than acetate. if the certificate does not say, you cannot do the mass balance

SN

the honest summary is that a certificate tells you what the supplier says about a lot they chose to test

SN

a lab that reports "greater than 98%" rather than a number is telling you they did not integrate carefully

LN

if the certificate date precedes the lot date, ask. sometimes it is sloppiness and sometimes it is not

lot        bought    purity   assay/label
A-2418     2025-03   99.1%    9.6 / 10mg
A-2601     2025-08   98.7%    9.8 / 10mg
B-0114     2026-01   99.3%    9.4 / 10mg
B-0329     2026-04   98.9%    9.9 / 10mg
20:33ferrous_ash pinned a message to this channel
LN

single wavelength detection can miss a co-eluting impurity that does not absorb there

update on the earlier thing an identical chromatogram on two different lots is the single biggest tell there is

📈3
SN

i asked SSA for the method and they sent it. that alone put them ahead of most

thats a tell

does anyone keep a folder of certificates to compare over time

🤝8

sterility and endotoxin are separate tests and almost nobody runs either on research material, we shall see

🤝1⚠️9🧪4