if the maths gives you 13.7 units, change the volume. do not try to hit 13.7
#reconstitution 2026-05-16
- seoul_swirl — the meniscus thing is real. read it at eye level or you are guessing by a unit either way 11:11
- truncation_tru — i keep a spare vial of bac water in the fridge purely so i never rush the maths 11:35
- deadspace — how much do i lose to dead space with a 29G pin 14:42
- lisbon_lot — i swirl for about thirty seconds and then leave it. never had one fail to dissolve 14:47
- VialBot — Archive lookup: deadspace first appears in this channel on 2025-12-01. 16:55
do i swirl for a specific length of time or just until its clear
is a slightly cloudy solution ever ok or is that always a bin it
right so my 10mg vial weighed 11.4g on the jewellery scale, is that wrong
30mg in 3ml is 10mg/ml, so 5mg is 50 units. half the barrel, feels like a lot but its right
if the powder is on the stopper, tap it down before you add anything. it will still dissolve either way
nobody here should be telling you a dose. we can check your arithmetic, thats a different thing
the meniscus thing is real. read it at eye level or you are guessing by a unit either way
nope, redo it
too dilute imo
coming back after 20 months, has the pinned recon volume advice changed
if i add 2.5ml to a 30mg vial what concentration am i actually at
not sterile water
i have never once regretted using a rounder number and a slightly bigger volume, your mileage will differ
i keep a spare vial of bac water in the fridge purely so i never rush the maths
dead space
can i add more bac water later to a vial ive already reconstituted
is the meniscus reading actually a real source of error or am i overthinking
if the powder is on the stopper, tap it down before you add anything. it will still dissolve either way
anyone worked out a recon volume that puts 0.25mg on a round unit mark
ok so it should be completely clear with no floaters. cloudy means stop
follow up the vacuum will pull it in. let it. fighting it is how you get a face full of aerosol
it foamed. is it ruined
dead space in a standard insulin syringe hub is small but it is not nothing over a month, someone check my working
update from 11 months ago: switched to a single concentration and have not miscalculated since
swirl it. do not shake it. the foam is denatured protein and you are not getting it back
quick one if you draw up with a bigger pin and inject with a fresh one you lose a bit more to dead space
a 3ml syringe for the diluent and a u100 for the dose is the setup most people here end up with
does benzyl alcohol matter if im finishing the vial in one go
thats the vacuum
pick the volume so your dose is a whole number of units. thats the entire trick, someone check my working
temperature of the diluent does not matter. how fast you push it in does
yep 10 units
a slightly collapsed cake is cosmetic. a puddle in the bottom is not
foam is bad
you can absolutely just always use 2ml, and honestly most of us should
how much do i lose to dead space with a 29G pin
the jewellery scale is a good habit but calibrate it, they drift badly
if you cannot read the mark confidently, your volume is too small. redo it at a lower concentration
i swirl for about thirty seconds and then leave it. never had one fail to dissolve
is it worth buying a 3ml syringe for the diluent or is the insulin one fine
weigh it first
bac water or sterile water for something im going into weekly for 2 weeks
how do you all measure a half unit, or do you just not
bac water
the last few units are a real loss. i accept it rather than tilting the vial and drawing air
weighing the vial before you reconstitute is the only way to catch an underfill, not advice obviously
label the vial
5mg in 2ml gives 2.5mg/ml, 0.25mg is 10 units. good for a starting dose
do you draw up with the same pin you inject with
Archive lookup: deadspace first appears in this channel on 2025-12-01.
round numbers