vialroom

#reconstitution 2026-03-03

Tuesday28 messages6 participantstimes are UTC
Highlights from this day
  • mcg_not_mg — the last few units are a real loss. i accept it rather than tilting the vial and drawing air temperature of the diluent does not matter. how fast you push it in does 17:59
  • VialBot — Recon calculator: 30mg in 5ml = 2mg/ml. 18:27
  • cold_pack_carla — follow up 30mg in 3ml is 10mg/ml, so 5mg is 50 units. half the barrel, feels like a lot but its right 18:30
  • cold_pack_carla — my vial pulled the water in on its own, is that the vacuum or did i do something 19:39
  • rotate_the_site — temperature of the diluent does not matter. how fast you push it in does if you cannot read the mark confidently, your volume is too small. redo it at a lower… 20:46
A1

10mg in 2ml is 5mg/ml. so 0.5mg is 0.1ml which is 10 units on a u100

[edited]

not sterile water

10mg in 1ml is 10mg/ml, so 2.5mg is 25 units. thats the one i use, thats one data point

MN

dead space in a standard insulin syringe hub is small but it is not nothing over a month

clear or bin it

MN

unrelated but bac water or sterile water for something im going into weekly for 5 weeks

MN

the last few units are a real loss. i accept it rather than tilting the vial and drawing air
temperature of the diluent does not matter. how fast you push it in does

dead space

swirl dont shake

CP

follow up 30mg in 3ml is 10mg/ml, so 5mg is 50 units. half the barrel, feels like a lot but its right

👀18⚠️7🙏11
CP

follow up 15mg in 3ml is 5mg/ml. same numbers as 10 in 2, just more of it, for what its worth

CP

my vial pulled the water in on its own, is that the vacuum or did i do something

📈15🧪9👀4

foam is bad

bac water

📈12👀4🤝1
A1

nobody here should be telling you a dose. we can check your arithmetic, thats a different thing

💀1

the jewellery scale is a good habit but calibrate it, they drift badly
bacteriostatic water for anything multi-use. sterile water has no preservative in it at all

MM

weighing the vial before you reconstitute is the only way to catch an underfill, i could be wrong

RT

took me a year to stop over-diluting. the measurement error at 4 units is worse than the convenience

RT

temperature of the diluent does not matter. how fast you push it in does
if you cannot read the mark confidently, your volume is too small. redo it at a lower concentration

CP

if the powder is on the stopper, tap it down before you add anything. it will still dissolve either way

if the maths gives you 13.7 units, change the volume. do not try to hit 13.7

MM

you can absolutely just always use 2ml, and honestly most of us should, still working it out