took me a year to stop over-diluting. the measurement error at 4 units is worse than the convenience
#reconstitution 2025-03-06
- declared_value — anyone else find the 15mg vials harder to get fully dissolved than the small ones if you cannot read the mark confidently, your volume is too small. redo it at a… 20:53
- VialBot — Inter-lab diff for lot C-4402: 99% vs 98.1%. Within expected range. 21:09
- apob_over_ldl — anyone got a photo of what a properly dissolved vial looks like 21:40
- VialBot — Purity check: no report on file for lot A-2601. Nothing logged either way. 22:28
- VialBot — Channel stats, last 30 days: 128 messages from 48 members. 22:37
On this day 5 years ago this channel logged 80 messages.
genuine question update from 6 months ago: switched to a single concentration and have not miscalculated since
swirl it. do not shake it. the foam is denatured protein and you are not getting it back
anyone else find the 15mg vials harder to get fully dissolved than the small ones
if you cannot read the mark confidently, your volume is too small. redo it at a lower concentration
U-100 syringe: 1 unit = 0.01 ml
10u = 0.10 ml
25u = 0.25 ml
50u = 0.50 ml
100u = 1.00 ml
mg drawn = ml drawn x mg/mlfor the archive how much do i lose to dead space with a 30G pin
write the date on
nobody here should be telling you a dose. we can check your arithmetic, thats a different thing
thats 5mg/ml
5mg in 2ml gives 2.5mg/ml, 0.25mg is 10 units. good for a starting dose
is it worth buying a 3ml syringe for the diluent or is the insulin one fine
Inter-lab diff for lot C-4402: 99% vs 98.1%. Within expected range.
my vial pulled the water in on its own, is that the vacuum or did i do something
the vacuum will pull it in. let it. fighting it is how you get a face full of aerosol
dead space in a standard insulin syringe hub is small but it is not nothing over a month, i could be wrong
read it at eye level
i have never once regretted using a rounder number and a slightly bigger volume, ymmv
i use bac water even for a single-use vial because it stings less, which is not the reason it exists, for what its worth
temperature of the diluent does not matter. how fast you push it in does
you can absolutely just always use 2ml, and honestly most of us should
do you let it come to room temp before drawing or draw it cold
anyone got a photo of what a properly dissolved vial looks like
too dilute imo
if you draw up with a bigger pin and inject with a fresh one you lose a bit more to dead space
thats fine
ok so do not add more bac water to an already reconstituted vial, you have lost track of the concentration
a slightly collapsed cake is cosmetic. a puddle in the bottom is not
[edited]whats the smallest volume you would trust yourself to measure on a u100
clear or bin it
[edited]it foamed. is it ruined
unrelated but temperature of the diluent does not matter. how fast you push it in does
what do you do with the last 5 units when you cant draw them cleanly
label the date too. you will not remember which vial is which by week 8, take that with a pinch of salt
check your maths
Purity check: no report on file for lot A-2601. Nothing logged either way.
Channel stats, last 30 days: 128 messages from 48 members.
while im here does it matter if i inject the bac water straight at the powder
round numbers
one unit is 0.01ml
not sterile water
foam is bad
i swirl for about thirty seconds and then leave it. never had one fail to dissolve
my rule is one concentration for everything so i never have to think about it at 7am
genuine question give it 3 minutes at room temperature before you decide it has not dissolved, not advice obviously
im getting bubbles in the barrel every single time, what am i doing wrong