do you draw up with the same pin you inject with
[edited]#reconstitution 2024-12-01
- electrolyte_eli — the meniscus thing is real. read it at eye level or you are guessing by a unit either way 21:21
- rezept_rolf — is the meniscus reading actually a real source of error or am i overthinking 21:46
- deadspace — how do you all measure a half unit, or do you just not 21:52
- deadspace — my vial pulled the water in on its own, is that the vacuum or did i do something 21:56
the powder is stuck to the stopper, do i care
i use bac water even for a single-use vial because it stings less, which is not the reason it exists
benzyl alcohol is what makes it bacteriostatic. it is about 0.9% typically
if the maths gives you 13.7 units, change the volume. do not try to hit 13.7
i was wrong about this last year: it is fine to draw cold, it just stings more going in, n of 1 obviously
the meniscus thing is real. read it at eye level or you are guessing by a unit either way
i swirl for about thirty seconds and then leave it. never had one fail to dissolve, still working it out
it should be completely clear with no floaters. cloudy means stop
temperature of the diluent does not matter. how fast you push it in does
the last few units are a real loss. i accept it rather than tilting the vial and drawing air
my rule is one concentration for everything so i never have to think about it at 7am
it foamed. is it ruined
thats fine
is the meniscus reading actually a real source of error or am i overthinking
how do you all measure a half unit, or do you just not
5mg in 2ml gives 2.5mg/ml, 0.25mg is 10 units. good for a starting dose
my vial pulled the water in on its own, is that the vacuum or did i do something
if you draw up with a bigger pin and inject with a fresh one you lose a bit more to dead space
how long after reconstituting before its actually dissolved
foam is bad
thats the vacuum
30mg in 3ml is 10mg/ml, so 5mg is 50 units. half the barrel, feels like a lot but its right
10mg in 2ml is 5mg/ml. so 0.5mg is 0.1ml which is 10 units on a u100, we shall see
one unit is 0.01ml
clear or bin it
[edited]weighing the vial before you reconstitute is the only way to catch an underfill
you can absolutely just always use 2ml, and honestly most of us should
bac water
do you let it come to room temp before drawing or draw it cold
aim the diluent at the glass wall, not at the powder. it goes in gentler, someone check my working
does temperature of the bac water matter at all
swirl it. do not shake it. the foam is denatured protein and you are not getting it back
label the vial
lyophilised powder is far more robust than people think. it is the solution that is fragile, thats one data point
sorry to jump in took me a year to stop over-diluting. the measurement error at 4 units is worse than the convenience
a 3ml syringe for the diluent and a u100 for the dose is the setup most people here end up with