  • mhra_unlicensed — net peptide is gross mass minus water minus counterion. that is why 11.4mg of powder can be a correct 10mg vial 18:49
  • mhra_unlicensed — no lot number, no certificate. a document you cannot tie to the vial in your hand is decoration, from memory 19:01
  • dog_person_dev — water content is why an honest 10mg vial assays at 9.1. karl fischer titration, and most certificates omit it 19:05
  • dog_person_dev — if you only read one line on a certificate, read the lot number. if you read two, read the assay 19:54
  • dog_person_dev — nobody can authenticate a certificate from a scan. you authenticate the material by testing it yourself 20:32
MU

net peptide is gross mass minus water minus counterion. that is why 11.4mg of powder can be a correct 10mg vial

an identical chromatogram on two different lots is the single biggest tell there is, we shall see

MU

no lot number, no certificate. a document you cannot tie to the vial in your hand is decoration, from memory

📈7💀10

if the certificate date precedes the lot date, ask. sometimes it is sloppiness and sometimes it is not

DP

water content is why an honest 10mg vial assays at 9.1. karl fischer titration, and most certificates omit it

DP

if you only read one line on a certificate, read the lot number. if you read two, read the assay

📈9
DP

nobody can authenticate a certificate from a scan. you authenticate the material by testing it yourself

site-rotation-map.png
1000 × 700 · 493 KB · not retained in the public archive

the three way match is vial, certificate, invoice. if all three agree you have something

MU

coming back to this is area percent the same thing as how many mg are in the vial

i have never seen a research certificate with an endotoxin result on it. not once