  • assay_not_purity — nobody can authenticate a certificate from a scan. you authenticate the material by testing it yourself 07:53
  • assay_not_purity — update from 9 months ago: started asking every supplier for water content and about half now include it 08:06
  • VialBot — Recon calculator: 10mg in 3ml = 2.5mg/ml. 09:06
  • two_lifts_a_week — residual solvents matter more than people think for anything that went through a lot of purification steps 09:09
  • blind_submit — update on the earlier thing water content is why an honest 10mg vial assays at 9.1. karl fischer titration, and most certificates omit it 12:33
AN

nobody can authenticate a certificate from a scan. you authenticate the material by testing it yourself

LineClaimsDoes not claim
Purity (area %)fraction of detected material that is the targethow many mg are in the vial
Assay / contentmg of target per vialthat it is sterile
Water contentmass fraction that is wateranything about purity
Counterionsalt form and its mass sharenet peptide unless stated
Related substanceswhat else was seenwhat was not looked for
AN

update from 9 months ago: started asking every supplier for water content and about half now include it

🔥5👀4🎉5
FF

a certificate should name the method, the instrument, the column and the operator. most name none of those

📈1😂1
TL

the honest summary is that a certificate tells you what the supplier says about a lot they chose to test

the font on this one changes halfway down, am i being paranoid

net peptide is gross mass minus water minus counterion. that is why 11.4mg of powder can be a correct 10mg vial

sorry to jump in the related substances table is the interesting part. a row of "not detected" means they did not look hard

an identical chromatogram on two different lots is the single biggest tell there is

🙏1❤️2
EE

ok so a lab that reports "greater than 98%" rather than a number is telling you they did not integrate carefully

the retention time on this one is different from the last lot, problem

looks re-dated

VB

Recon calculator: 10mg in 3ml = 2.5mg/ml.

👀1🧪6
TL

residual solvents matter more than people think for anything that went through a lot of purification steps

🤝17

sterility and endotoxin are separate tests and almost nobody runs either on research material

VB

Digest for the week of 2026-01-16 has been published.

KF

sorry to jump in mixed fonts and inconsistent kerning in one document is worth a second look

❤️9

update on the earlier thing coming back after 17 months, has the pinned reading guide changed

purity is what fraction of the contents is the target. assay is how many mg are actually there. different questions

CP

retention time shifts between runs are normal. relative retention time is the number to compare
residual solvents matter more than people think for anything that went through a lot of purification steps

quick one how do you verify a certificate is actually from the lab it says

[edited]
BS

follow up two certificates from the same supplier have an identical chromatogram, is that normal

TL

if the certificate date precedes the lot date, ask. sometimes it is sloppiness and sometimes it is not

👀4
CP

no lot number, no certificate. a document you cannot tie to the vial in your hand is decoration

is endotoxin ever tested on research material

coming back to this is a supplier certificate worth anything on its own

single wavelength detection can miss a co-eluting impurity that does not absorb there

i was wrong about this for a year: area percent under-reports nothing, it just answers a different question than assay does

same chromatogram

lot-log.csv
639 rows · not retained in the public archive
BS

i keep every certificate in a dated folder and compare them. two suppliers had not changed their template since 2019