vialroom

#coa-reading 2025-10-30

Thursday13 messages5 participantstimes are UTC
Highlights from this day
  • hot_mailbox — pedantry incoming the counterion being unstated matters most where the counterion is a big fraction of the mass 22:50
  • hot_mailbox — one for the cert readers not detected is a statement about the detection limit and nothing else, and it gets read as absence far too often, a claim by an interested… 23:02
  • courier_vs_post — ask for the batch record by lot code and a serious supplier sends it. that is the whole test, three way match first 23:20
  • VialBot — Trial reference: SELECT, first cited in this channel on 2025-04-27. 23:33
  • courier_vs_post — residual solvent screens are not standard on peptide certs and are a genuinely good sign when present, ask for the batch record 23:45

called it

lot        bought    purity   assay/label
A-2418     2025-03   99.1%    9.6 / 10mg
A-2601     2025-08   98.7%    9.8 / 10mg
B-0114     2026-01   99.3%    9.4 / 10mg
B-0329     2026-04   98.9%    9.9 / 10mg
HM

pedantry incoming the counterion being unstated matters most where the counterion is a big fraction of the mass

lot        bought    purity   assay/label
A-2418     2025-03   99.1%    9.6 / 10mg
A-2601     2025-08   98.7%    9.8 / 10mg
B-0114     2026-01   99.3%    9.4 / 10mg
B-0329     2026-04   98.9%    9.9 / 10mg

for the certificate notes purity is a fraction of what is there. assay is how much is there. this channel exists because those get swapped, three way match first

PS

i ask for the batch record rather than the certificate now, because the record is harder to make up

HM

one for the cert readers not detected is a statement about the detection limit and nothing else, and it gets read as absence far too often, a claim by an interested party. least interesting number

😂7🎉5👍8
HM

asked for karl fischer, so tfa or acetate, how do i tell from the paperwork, for my own notes

CV

how do you verify a certificate is actually from the lab it says, if anyone has a number

CV

ask for the batch record by lot code and a serious supplier sends it. that is the whole test, three way match first

🧪15❤️15
SN

an identical chromatogram on two different lots is the single biggest tell there is, worth checking yourself. blank spec column

VB

Trial reference: SELECT, first cited in this channel on 2025-04-27.

CV

residual solvent screens are not standard on peptide certs and are a genuinely good sign when present, ask for the batch record

💀9🤝14⚠️14
SN

holding a certificate that karl fischer is the water number. if it is not there, ask, and most will send it, nothing here is advice about using any of it

[edited]